📘 Salt System Troubleshooting Field Guide

Quick resets, common failures, salt ranges, and error code troubleshooting for Jandy AquaPure and TruClear, Hayward AquaRite 900, and Pentair IntelliChlor and IntelliChlor+.

Download PDF (opens or saves the file)

Searchable text version of the salt system field guide. Confirm details against the manufacturer's manual. * Low temps can trigger a false low salt error.

Salt systems at a glance
ModelSalt rangeVolts / ampsMost common failure
Jandy AquaPure3000–3500 ppm22–30V / 4–7A (PLC1400)Tri-Sensor drift (flow, temp, salt)
Jandy TruClear3000–3500 ppmNot displayedFlow detection (RPM too low)
Hayward AquaRite 9002700–3400 ppm (ideal 3200)22–26V / 4.5–7.0AFlow switch not closing
Pentair IntelliChlor3000–4500 ppm (ideal 3600)Not visibleLow flow (pump RPM too low for flow switch)
Pentair IntelliChlor+3000–4500 ppm (ideal 3600); will not produce over 4000 ppm22–30V / 4–8A, depending on modelIncorrect salinity reading

Learn more: Salt cells: chemistry and why they fail ›

Jandy AquaPure: reset and error codes
CodeMeaningWhat to do
120Low currentIf under 4 amps, check and clean the cell
121Low current during reverse polarityPower cycle and clean the cell
123Low current, recurringCheck salt. If salt is in range, the cell is bad*
125Clean cellIf the cell is clean, the tri-sensor is bad
144Low salt*If salt is in range, the sensor is bad
172Flow sensor faultBoost pump speed and clean the filter. If flow is good, the sensor is bad
175Flow sensor fault, recurringUnless flow, salt, or scale is persistently a problem, the sensor is failing or has failed
Jandy TruClear: reset and troubleshooting
Hayward AquaRite 900: reset, troubleshooting, and changing cell types Changing cell types
Pentair IntelliChlor: reset and troubleshooting
Pentair IntelliChlor+: reset, troubleshooting, and message definitions
MessageMeaning / what to do
ADD SALTSalt is trending low
SYS OFF / SENS ERRTemporary error while the cell is rebooting
SPAREHMI is ready to pair with the cell after reboot
CHECK CELLInspect everything
CLEAN CELLEfficiency drop detected. Only clean the cell if scale is present. Can also indicate end of life
CELL FAULTEnsure voltage is in range, check the cable, inspect for scale, reset at the breaker
SANITIZER OFFInspect everything
OUTPUT LIMITEDLow salt, high salt, cold water, or marginal flow
CELL RESTINGPolarity reversal. Normal, wait 30 sec
NO CELL / CELL NOT DETECTEDInspect the cable and connection, reset, repair HMI
⚠️ Professional note